Tabula Universalis ModuFlow 0-10V XF58625
Informationes Fundamentales
| Numerus Modeli | Magnitudo | Typus Emissionis | Currens |
| XF58625 | 86 * 86mm | ON/OFF | 3A |
| Accuratio | Ambitus Temperaturae Constituendae | Ambitus Temperaturae Ostentandae | Ambitus Laboris | Typus Sensoris |
| ±0.5°C | 5°C – 35°C | 0°C – 55°C (Ostendit "HI" > 55°C, "LO" < 0°C) | 0°C – 50°C | NTC (10k) 1% |
Singula Producti
| 物品 | 描述 | 参数范围 | 默认 |
| A1 | 温度安排 | -9 +9% | |
| A2 | 儿童锁模式 | 0:半锁;1:全锁;2:解锁 | 0 |
| A3 | 最低温度限制 | 5–15°C | 5°C |
| A4 | 最高温度限制 | 16–50°C | 35°C |
| A5 | 风扇节能 | 0:风扇关闭(阀门开关);1:风扇风扇开关 | 0 |
| A6 | 即时模式 | 0:5+2;1:6+1;2:7天;3:无计划 | 0 |
| A7 | 阀门管道选择 | 2:两控制系统;4:四控制系统 | 4 |
| A8 | 传感器选择 | N1:内部;N2:外部;N3:两者兼有 | N1 |
| A9 | 外部传感器 | 20–60°C | 38°C |
| AA | 无力 | 0:关闭;1:弱;2:强 | 2 |
| AB-AD) | |||
| 这些设置定义了风扇在不同的电压下的电压输出 | |||
| 物品 | 描述 | 电压范围 | 默认 |
| AB | 低速 | 10%–30% (0.5–3V) | 10 |
| 交流电 | 中速 | 30%–75% (3.5–7.5V) | 50 |
| 广告 | 高速 | 80%–100% (8.0–10V) | centum |
| B(B1-B2) | |||
| 物品 | 描述 | 参数范围 | 默认 |
| B1 | IP低地址 | 01–FF | 1 |
| B2 | 波特率 | 0:2400;1:4800;2:9600 | 2 (9600) |
| 核心技术规范 | |||
| ±0.5℃ | |||
| 5°C 35°C | |||
| -0 至 55 °C(55 °C " HI",低于 0 °C "LO") | |||
| 传感器类型:NTC(10k)1% | |||
Excellentia Ingeniaria et Designationis Fabricae
Praecisio moderationis industrialis summa
Praecisio Moderationis Temperaturae: ±0.5°C
Typus Sensoris: NTC (10k) ±1% Thermistor Altae Praecisionis
Gradus/Incrementum Adaptationis: 0.5°C Adaptatio Subtilis
Imperium Tensionis Ventilatoris Programmabile (Egressus 0-10V)
Modulatio Continua, Formae Tensionis Trium Velocitatum Adaptabiles
Per optiones provectas AB, AC, et AD, usores tensionem egressam specificam pro celeritatibus Humili, Medio, et Alto (a 0.5V ad 10V adaptabilem) definire possunt. Hoc compatibilitatem perfectam cum variis generibus coil ventilorum praestat et problemata ad strepitum ventilatorum vel discrepantiam fluxus aëris pertinentia efficaciter solvit.
Logica Conservationis Energiae
Modus Energiae Conservandae Intelligentis: Per parametrum A5, usores "Modum Energiae Conservandae" configurare possunt. Postquam temperatura desiderata attingitur et valvula aquae clauditur, systema automatice determinat utrum ventilabrum exstinguere an circulationem parvae potentiae servare debeat. Efficientiam energiae "Ad Postulationem" praecisam, secundum requisita cubiculi in tempore reali, assequitur.
Modi Configurationis Sensorum (Optiones Provectae: N1, N2, N3)
N1:N1: Sensorium Internum Solum
N2: Sola Externa Probatio
N3: Modus Dualis Sensoris Moderatio Dualis Temperaturae
In hoc modo, sensor externus temperaturam pavimenti ad protectionem contra nimium calorem observat (limen protectionis per parametrum A9 aptari potest), dum sensor internus temperaturam ambientis cubiculi moderatur.
Proprietates Claves
XF58625 praecisionem ±0.5°C, exitum ventilatoris 0-10V configurabilem praebet, et systemata Modbus et 2/4-tubularia sustinet. Solutio callida et flexibilis est ad aedificia industrialia moderanda.
Gradus Processus
Materia Rudis, Fabricatio Fusa, Fusio Ruvida, Fundatio, Machinatio CNC, Inspectio, Examen Effluxionis, Compositio, Horreum, Navigatio
Examen Materiarum, Horreum Materiarum Crudarum, Immissio Materiae, Auto-Inspectio, Prima Inspectio, Inspectio Circularis, Cuditura, Recoctio, Auto-Inspectio, Prima Inspectio, Inspectio Circularis, Machinatio, Auto-Inspectio, Prima Inspectio, Inspectio Circularis, Inspectio Perfecta, Horreum Semi-Perfectum, Compositio, Prima Inspectio, Inspectio Circularis, Examen Sigilli 100%, Inspectio Fortuita Finalis, Horreum Producti Perfecti, Traditio
Mercatus Exportationis Praecipui
Europa, Europa Orientalis, Russia, Asia Media, America Septentrionalis, America Meridionalis et cetera.
Quaestiones Frequentes
XF58625 praecisionem ±0.5°C, exitum ventilatoris 0-10V configurabilem praebet, et systemata Modbus et 2/4-tubularia sustinet. Solutio callida et flexibilis est ad aedificia industrialia moderanda.
.
0(同步):风扇在水阀关闭时同时关闭以节省电力
1(持续):即使水阀关闭,风扇也会继续运转,以保持持续的空气循环
12,000
.