Chinese Professional Exhaust Valve - Brass air vent valve – Xinfan

Basic Info

Product Detail

Product Tags

Related Video

Feedback (2)

owing to good service, a variety of high quality products, competitive prices and efficient delivery, we enjoy a good reputation among our customers. We are an energetic company with wide market for Manuel Radiator Valve, Drain Relief Valve, Brass Underfloor Heating Control System, Aggressive price with top quality and satisfying support make us earned extra customers.we wish to work along with you and request common enhancement.
Chinese Professional Exhaust Valve - Brass air vent valve – Xinfan Detail:

Product Details

Warranty: 2 Years Number: XF90970
After-sale Service: Online technical support Type: Floor Heating Systems
Style: Modern Keywords: Air vent valve
Brand Name: SUNFLY Color: Nickel plated
Application: Apartment Design Size: 1/2’’ 3/8’’ 3/4’’
Name: Brass radiator valve MOQ: 200 pcs
Place of Origin: Zhejiang, China
Brass Project Solution Capability: Graphic design, 3D model design, total solution for  Projects, Cross Categories Consolidation

Product parameters

   Vent valve XF90970

Model: XF90970

3/8”
1/2”
3/4’’

 

asd (2)  

A

 

B

 

C

 

D

 

3/4”

 

15

 

90.5

 

37

 

1”

 

15

 

90.5

 

37

Product material

Hpb57-3,Hpb58-2,Hpb59-1,CW617N,CW603N,or Customer designated other copper materials 

Processing Steps

Anti-burns constant temperature mixed water valve (2)

Raw Material, Forging,Roughcast,Slinging, CNC Machining,Inspection,Leaking Test, Assembly,Warehouse,Shipping

Production Process

Material Testing, Raw Material Warehouse, Put In Material, Self-Inspection, First Inspection, Circle Inspection, Forging, Annealing, Self-Inspection, First Inspection, Circle Inspection, Machining, Self-Inspection, First Inspection, Circle Inspection, Finished Inspection, Semi-Finished Warehouse, Assembling, First Inspection, Circle Inspection, 100% Seal Testing, Final Random Inspection, Finished Product Warehouse, Delivering

Applications

Air vent are used in independent heating systems, central heating systems, heating boilers, central air conditioning, floor heating and solar heating systems and other pipeline exhaust.

Anti-burns constant temperature mixed water valve (7)

Main Export Markets

Europe,East-Europe,Russia,Middle-Asia,North America,South America and so on.

Installation instructions:

The device is delivered to the consumer completely ready for use and does not require additional adjustment.

Before installing the air vent, the pipeline must be cleaned of rust, dirt, scale, sand and other foreign particles that affect the performance of the device. Heating,internal cold and hot ater supply systems, boiler pipelines at the end of their installation must be flushed with water until it comes out without mechanical suspensions .

The air vent must be installed in a vertical position with the protective cap up (with connection on a cylindrical pipe thread according ) in places where air and gas can accumulate (the highest points of piping systems, air collectors, boilers, collectors, heating devices).

The air vent should not experience external loads: vibration, uneven tightening of fasteners . It is allowed to install an air vent without a shut-off valve – if there are shut-off valves nearby on the pipeline and there are no other strict system requirements.It is not allowed to carry out hydraulic tests of the system with installed air vents or with shutoff valves open in front of them. No load on the protective cap is permitted.

The air vent must be securely fixed to the pipeline, leakage of the working fluid through the threaded part is unacceptable. Threaded connections should be made using FUM tape (PTFE-polytetrafluoroethylene, fluoroplastic sealing material), polyamide yarn with silicone or linen as winding sealing material. In this case,it is necessary to ensure that excess of this material does not fall on the shut-off valve seat. This may cause the valve to become inoperative. Check for proper installation.

After installation, a manometric system leak test should be performed. This test allows you to protect the system from leaks and damage associated with them.To bring the air vent into operation, it is necessary to unscrew a little (without removing) the protective cap located at the top of the cover.


Product detail pictures:

Chinese Professional Exhaust Valve - Brass air vent valve – Xinfan detail pictures


Related Product Guide:

we are able to provide good quality items, aggressive rate and best shopper assistance. Our destination is "You come here with difficulty and we provide you with a smile to take away" for Chinese Professional Exhaust Valve - Brass air vent valve – Xinfan , The product will supply to all over the world, such as: Nairobi, Costa Rica, Korea, Good quality and reasonable price have brought us stable customers and high reputation. Providing 'Quality Products, Excellent Service, Competitive Prices and Prompt Delivery', we are now looking forward to even greater cooperation with overseas customers based on mutual benefits. We'll work whole-heartedly to improve our solutions and services. We also promise to work jointly with business partners to elevate our cooperation to a higher level and share success together. Warmly welcome you to visit our factory sincerely.
  • The sales manager is very patient, we communicated about three days before we decided to cooperate, finally, we are very satisfied with this cooperation!
    5 Stars By lucia from Pretoria - 2017.11.11 11:41
    The after-sale warranty service is timely and thoughtful, encounter problems can be resolved very quickly, we feel reliable and secure.
    5 Stars By Louis from Belgium - 2017.02.14 13:19
    Write your message here and send it to us