Factory wholesale Auto Air Release Valve - Brass air vent valve – Xinfan

Basic Info

Product Detail

Related Video

Feedback (2)

"Control the standard by the details, show the toughness by quality". Our firm has strived to establish a highly efficient and stable workers workforce and explored an effective high-quality management system for Floor Heating Smart Panel, Water Underfloor Manifold, Temperature-Sensing Valve, Our hugely specialized process eliminates the component failure and offers our consumers unvarying high quality, allowing us to control cost, plan capacity and maintain consistent on time delivery.
Factory wholesale Auto Air Release Valve - Brass air vent valve – Xinfan Detail:

Product Details

Warranty: 2 Years Number: XF90970
After-sale Service: Online technical support Type: Floor Heating Systems
Style: Modern Keywords: Air vent valve
Brand Name: SUNFLY Color: Nickel plated
Application: Apartment Design Size: 1/2’’ 3/8’’ 3/4’’
Name: Brass radiator valve MOQ: 200 pcs
Place of Origin: Zhejiang, China
Brass Project Solution Capability: Graphic design, 3D model design, total solution for  Projects, Cross Categories Consolidation

Product parameters

   Vent valve XF90970

Model: XF90970

3/8”
1/2”
3/4’’

 

asd (2)  

A

 

B

 

C

 

D

 

3/4”

 

15

 

90.5

 

37

 

1”

 

15

 

90.5

 

37

Product material

Hpb57-3,Hpb58-2,Hpb59-1,CW617N,CW603N,or Customer designated other copper materials 

Processing Steps

Anti-burns constant temperature mixed water valve (2)

Raw Material, Forging,Roughcast,Slinging, CNC Machining,Inspection,Leaking Test, Assembly,Warehouse,Shipping

Production Process

Material Testing, Raw Material Warehouse, Put In Material, Self-Inspection, First Inspection, Circle Inspection, Forging, Annealing, Self-Inspection, First Inspection, Circle Inspection, Machining, Self-Inspection, First Inspection, Circle Inspection, Finished Inspection, Semi-Finished Warehouse, Assembling, First Inspection, Circle Inspection, 100% Seal Testing, Final Random Inspection, Finished Product Warehouse, Delivering

Applications

Air vent are used in independent heating systems, central heating systems, heating boilers, central air conditioning, floor heating and solar heating systems and other pipeline exhaust.

Anti-burns constant temperature mixed water valve (7)

Main Export Markets

Europe,East-Europe,Russia,Middle-Asia,North America,South America and so on.

Installation instructions:

The device is delivered to the consumer completely ready for use and does not require additional adjustment.

Before installing the air vent, the pipeline must be cleaned of rust, dirt, scale, sand and other foreign particles that affect the performance of the device. Heating,internal cold and hot ater supply systems, boiler pipelines at the end of their installation must be flushed with water until it comes out without mechanical suspensions .

The air vent must be installed in a vertical position with the protective cap up (with connection on a cylindrical pipe thread according ) in places where air and gas can accumulate (the highest points of piping systems, air collectors, boilers, collectors, heating devices).

The air vent should not experience external loads: vibration, uneven tightening of fasteners . It is allowed to install an air vent without a shut-off valve – if there are shut-off valves nearby on the pipeline and there are no other strict system requirements.It is not allowed to carry out hydraulic tests of the system with installed air vents or with shutoff valves open in front of them. No load on the protective cap is permitted.

The air vent must be securely fixed to the pipeline, leakage of the working fluid through the threaded part is unacceptable. Threaded connections should be made using FUM tape (PTFE-polytetrafluoroethylene, fluoroplastic sealing material), polyamide yarn with silicone or linen as winding sealing material. In this case,it is necessary to ensure that excess of this material does not fall on the shut-off valve seat. This may cause the valve to become inoperative. Check for proper installation.

After installation, a manometric system leak test should be performed. This test allows you to protect the system from leaks and damage associated with them.To bring the air vent into operation, it is necessary to unscrew a little (without removing) the protective cap located at the top of the cover.


Product detail pictures:

Factory wholesale Auto Air Release Valve - Brass air vent valve – Xinfan detail pictures


Related Product Guide:

Our well-equipped facilities and excellent excellent management throughout all stages of creation enables us to guarantee total buyer satisfaction for Factory wholesale Auto Air Release Valve - Brass air vent valve – Xinfan , The product will supply to all over the world, such as: Mumbai, Ecuador, Australia, We can meet the various needs of customers at home and abroad. We welcome new and old customers to come to consult & negotiate with us. Your satisfaction is our motivation! Let us work together to write a brilliant new chapter!
The customer service reprersentative explained very detailed, service attitude is very good, reply is very timely and comprehensive, a happy communication! We hope to have a opportunity to cooperate.
5 Stars By Anne from Guyana - 2017.06.25 12:48
We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
5 Stars By Christopher Mabey from Tunisia - 2018.02.12 14:52
Write your message here and send it to us