Our personnel are always in the spirit of "continuous improvement and excellence", and together with the top-quality good quality solutions, favorable selling price and superior after-sales providers, we try to acquire each customer's rely on for Exhaust Cutout Valve, Thermostatic Mixing Valve, Cw617n Ball Valve, We sincerely welcome friends from all over the world to cooperate with us on the basis of long-term mutual benefits.
Renewable Design for 3 Ways Mixing Valve - Underfloor Heating Mixing Water System – Xinfan Detail:

Warranty: 2 Years Number: XF15189E/XF15189D
After-sale Service: Online technical support Type: Floor Heating Systems
Style: Modern Keywords: Brass Mixing water system
Brand Name: SUNFLY Color: Nickel plated
Application: Apartment Size: 1”
Name: Mixing water system MOQ: 5 sets
Place of Origin: Zhejiang
Brass Project Solution Capability: Graphic design, 3D model design, total solution for  Projects, Cross Categories Consolidation

Product parameters

Mixing System XF15189E+XF15198D

CODE:XF15189E / XF15189D

Specifications

SIZE:1”

 

cdsvsg

A: 1’’

B: 1’

C: 124

D: 120

L: 210

Product material

Brass Hpb57-3(Accept customer-specified)

Processing Steps

csdvcdb

Raw Material, Forging, Roughcast, Slinging,  CNC Machining, Inspection, Leaking Test, Assembly, Warehouse, Shipping

cscvd

Material Testing, Raw Material Warehouse, Put In Material, Self-Inspection, First Inspection, Circle Inspection, Forging, Annealing, Self-Inspection, First Inspection, Circle Inspection, Machining, Self-Inspection, First Inspection, Circle Inspection, Finished Inspection, Semi-Finished Warehouse, Assembling, First Inspection, Circle Inspection, 100% Seal Testing, Final Random Inspection, Finished Product Warehouse, Delivering

Applications

Hot or cold water, manifold for floor heating, heating system, mix water system, construction materials etc.

dsafgh
dassdg

Main Export Markets

Europe,East-Europe,Russia,Middle-Asia,North America,South America and so on.

Product Description

1.working principle

the temperature control valve head sets the mixed water temperature and operates according to the pointer’s corresponding temperature mark; the temperature sensing package measures the mixed water temperature,and controls the mixed water ratio and the mixing temperature through the power part in the temperature control valve head;the front end receives the water separator,dividable control of high temperature heat sinks and towel racks for return water;undistributed water collectors. Controlled floor heating warm water is not higher than 60℃。The by-pass is used to ensure the minimum flow at the primary side and stabilize the primary pressure differential to avoid high temperature faults and water flow faults of the unti,affecting the heating effect,saving 20% energy,small installation volum,and optimal concentration control heating system.

2. Features

1.Sensor type mixed water cooling system. Through the temperature control sensor, the proportion of hot water and water is controlled by the temperature control package. The main body is forged, high-density, stable and reliable. And can increase the flow rate through the circulation pump, accelerate the heat dissipation effect can be used with all kinds of floor heating manifold;

2.The main body is forged as a whole, without leakage. The internationally leading shielded pump ,low power consumption (minimum of 46, up to 100 watts), 45 db low noise, long life, sustainable work 5000 h (water), stable and reliable

3.Proportional integral control water temperature, temperature difference ± 1C

4.Inching function: the shield pump is inched for 30 seconds every week to prevent the pump from locking due to

long-term stagnation;

5.It has the functions of filtration, drainage and exhaust, which is convenient for cleaning, overhaul and maintenance.

6.It has its own low-temperature protection function. When the water temperature is lower than 35 ° C, the system water pump stop, thus effectively protect the pump will not be dry and damaged the pump

7.It adopts the intelligent panel control, which can execute the system work by weekly programming setting, smart panel can automatically control the whole heating system to run automatically every hour a week


Product detail pictures:

Renewable Design for 3 Ways Mixing Valve - Underfloor Heating Mixing Water System – Xinfan detail pictures

Renewable Design for 3 Ways Mixing Valve - Underfloor Heating Mixing Water System – Xinfan detail pictures

Renewable Design for 3 Ways Mixing Valve - Underfloor Heating Mixing Water System – Xinfan detail pictures


Related Product Guide:

Our concentrate on should be to consolidate and enhance the quality and service of present products, meanwhile consistently produce new products to meet unique customers' demands for Renewable Design for 3 Ways Mixing Valve - Underfloor Heating Mixing Water System – Xinfan , The product will supply to all over the world, such as: Irish, Latvia, Greece, The credibility is the priority, and the service is the vitality. We promise we have now the ability to offer excellent quality and reasonable price items for customers. With us, your safety is guaranteed.
  • In China, we have many partners, this company is the most satisfying to us, reliable quality and good credit, it is worth appreciation.
    5 Stars By Mabel from Cambodia - 2018.09.23 18:44
    We are long-term partners, there is no disappointment every time, we hope to maintain this friendship later!
    5 Stars By Miguel from Turin - 2018.06.26 19:27
    Write your message here and send it to us